Command reference¶
ppk2 does from a terminal what the Power Profiler app does
with a PPK2: find it, switch power to the device under test (DUT), and
record current and digital inputs to a file. python -m ppk2 is the
same program, and every command has --help.
Only one program can hold a PPK2. Quit the app before you start.
| Command | What it does |
|---|---|
ppk2 list |
Shows the PPK2s attached and the state of their ports |
ppk2 discover |
Prints the path of the data port |
ppk2 metadata |
Prints the calibration |
ppk2 capture |
Records to a CSV or a .ppk2 file |
ppk2 convert |
Turns a CSV into a .ppk2 file |
ppk2 power |
Switches power to the DUT |
ppk2 run |
Runs a command with the DUT powered |
ppk2 version |
Prints the version |
Common options¶
| Option | Default | Accepted by | Meaning |
|---|---|---|---|
--serial TEXT |
none | discover, metadata, power, capture, run |
The USB serial number of one PPK2. Needed when several are attached |
--port PATH |
none | discover, metadata, power, capture, run |
The path of the data port. Skips the search |
--vdd FLOAT |
3.3 | power, capture, run |
The DUT's supply voltage in volts. A value outside 0.8 to 5.0 is brought back to the nearest of the two |
--source |
off | power, capture, run |
Source meter mode instead of Ampere meter mode |
--vdd means two things:
- In Source meter mode, it is the voltage the PPK2 supplies.
- In Ampere meter mode, it sets nothing, but the calibration uses it: give the voltage the DUT really runs at.
Exit codes¶
| Code | Meaning |
|---|---|
| 0 | Done |
| 1 | An error with the PPK2, the session or the output file, with a one-line message. Also a capture that ends with fewer samples than --seconds asks for |
| 2 | Wrong usage |
| 130 | Stopped by Ctrl-C |
ppk2 run returns the exit code of its command instead:
- 127 if the command was not found;
- 128 plus the signal number if a signal killed it.
An error is one line starting with error:. See
troubleshooting for the list. A wrong option or
value is reported with the usage line of the command.
ppk2 list¶
$ ppk2 list
PPK2 serial=A1B2C3D4E5F6
/dev/cu.usbmodemA1B2C3D4E5F62 [data port]
/dev/cu.usbmodemA1B2C3D4E5F64 [idle]
One block per PPK2, with a mark on each port:
[data port]: the port that answers;[idle]: the other one;[busy: held by another process?]: the port could not be opened. Close the program that holds it.
--mask-serial prints only the last four characters of each serial
number, in the port paths too. It is meant for a screenshot or a
recording; the masked paths are not usable as --port.
The exit code is 0 when every PPK2 has its data port identified, and 1
otherwise. If no PPK2 is attached, it prints no PPK2 found. If a
data port could not be identified, it says so under that PPK2.
ppk2 discover¶
Prints the path of the data port, for use in a script. It fails when no
PPK2 is attached, and when several are and --serial is missing.
ppk2 metadata¶
$ ppk2 metadata
Calibrated: false
HW: 46575
IA: 60
VDD: 3300 mV
mode: 2 (Source meter)
R : [ 1.002119e+03, 1.014783e+02, 1.033613e+01, 9.682840e-01, 5.643343e-02]
GS: [ 1.000000e-19, 1.258190e+02, 1.955098e+01, 2.673501e+00, 7.893860e-02]
GI: [ 1.000000e+00, 9.650117e-01, 9.590379e-01, 9.480509e-01, 9.562991e-01]
O : [ 1.229457e+02, 8.335670e+01, 7.085423e+01, 5.442371e+01, 9.623315e+01]
S : [ -7.046158e-09, 5.256595e-08, 4.921795e-07, 9.235569e-06, 2.415189e-03]
I : [ 5.155071e-08, -2.181893e-07, 5.512471e-05, -2.677141e-04, -8.630627e-03]
UG: [ 1.000000e+00, 1.000000e+00, 1.000000e+00, 1.000000e+00, 1.000000e+00]
It prints the calibration the PPK2 reports, five values per line, one
per measurement range. VDD and mode are the supply voltage and the
mode the PPK2 was left in. See the
Principle page
for what each line is, and why Calibrated: false is not a fault.
ppk2 capture¶
$ ppk2 capture --out first.csv --seconds 5 --source --vdd 3.3
opening session (Source meter mode, vdd=3300 mV)
capturing 5.00 s -> first.csv (Ctrl-C to stop early)
[ 1.0s] 100249 samples mean 945.69 µA
[ 2.0s] 199681 samples mean 826.16 µA
[ 3.0s] 300033 samples mean 783.65 µA
[ 4.0s] 400385 samples mean 761.46 µA
captured 500000 samples over 5.00 s (99936 Hz)
| Option | Default | Meaning |
|---|---|---|
--out, -o PATH |
required | The file to write. A name ending in .ppk2, in any letter case, gives a session file, any other name a CSV |
--seconds, -s FLOAT |
30 | How long to capture, as seconds of samples |
--user-gain RANGE:GAIN |
none | A gain from 0.9 to 1.1 for one range, 0 to 4. Can be repeated. See gains |
What to know about a capture:
- It switches the DUT on as it starts and off as it ends, in both modes, so the boot is in the file. The current rises about 10 ms into it. This is a choice: every capture starts from a DUT that is off. In Source meter mode the PPK2 is the supply, and in Ampere meter mode it sits in series with it, so in both the switch is in the DUT's power path.
- It ends when the file holds the seconds asked for: 500,000 samples for 5 s. If they have not all come one second after that time, it stops, keeps the file and exits with 1.
- Progress goes to the terminal once per second, the samples go to the file only.
- Currents below 0.2 µA are written as 0, as the app does.
- Ctrl-C stops early, completes the file and exits with 130.
- If samples were lost, the summary says how many. It also warns when the rate over the capture fell below 95,000 samples per second.
See File formats for both kinds of file.
ppk2 convert¶
Turns a CSV capture, plain or gzipped, into a .ppk2 session file.
The CSV needs:
- the
Timestamp(ms)andCurrent(uA)columns. The digital inputs are read fromD0-D7if the column is there. - a sample rate, taken from the timestamps, that is a power of ten up to 100,000.
- digital inputs that are
0or1. The-andXthat the app writes when it exports at a lower rate are not accepted.
A gap in the timestamps is filled with samples of 0.2 µA, the way a lost sample is recorded. A gap of more than one second is refused, and so are timestamps that go back. If the conversion fails, an earlier file of the same name is left as it was.
ppk2 power¶
Switches power to the DUT, as the app's Enable power output does.
Power lasts only while the command runs, because the PPK2 cuts it when
its serial port closes. So ppk2 power on without --hold powers the
DUT for an instant only, which is of little use. With --hold it waits
for Ctrl-C. --hold is not supported on Windows yet.
ppk2 run¶
Runs the command after -- with the DUT powered, and returns its exit
code. With --out it records while the command runs, to a CSV or a
.ppk2 file. It reads the stream in a second thread for that time,
with or without --out, since the PPK2 cannot be told to pause.
Ctrl-C is passed on to the command. When ppk2 run itself is
terminated, by kill or a closed terminal, it terminates the command
first, and kills it if it has not ended after 5 s. However the command
ends, the DUT is unpowered afterwards. The usual reason to use it is
flashing.
Signals¶
Ctrl-C, kill and a closed terminal all end a command the same way:
- the stream is stopped;
- the DUT is switched off;
- the port is closed;
- the output file is completed.
The exit code is 130 after Ctrl-C, and 128 plus the signal number after
kill or a closed terminal. ppk2 power on --hold is the exception:
Ctrl-C is how it is meant to end, and it returns 0.
If the process is killed outright, with kill -9, the PPK2 still cuts
power by itself, but it keeps streaming. The next ppk2 command stops
that stream when it opens the PPK2.