Skip to content

Getting started

From nothing to a first capture in six steps: install, wire, check, capture, read, and open the capture in the app.

Step 1: installation

Install it from PyPI:

pip install ppk2-lib

If you only want the command, uv installs it as a tool, in an environment of its own:

uv tool install ppk2-lib

To run it once without installing anything, use uvx --from ppk2-lib ppk2 list.

This gives you the ppk2 command and the ppk2 Python package. You need Python 3.11 or newer. Two dependencies come with it, pyserial and typer; there is nothing to compile.

$ ppk2 version
0.1.0

In a project of your own, add it as a dependency, here with uv:

uv add ppk2-lib

What it has been tested on:

Linux macOS Windows
Unit tests, Python 3.11 and 3.13 yes yes yes
Tests with a PPK2 on a bench no yes, macOS 26 no

The package is written for the three systems and uses nothing that is specific to one of them: pyserial handles the serial port on each. So far, the tests that need a PPK2 on a bench have run on a Mac only.

Step 2: wiring

Wire it as you would for the Power Profiler app. The PPK2 has two modes, named here as in the app, and the wiring decides which one you use. See Nordic's PPK2 user guide for both wirings on a dev kit, for the Ampere meter and for the Source meter.

Ampere meter mode

The device under test (DUT) has its own supply and the PPK2 sits in series with it. This is the default.

  supply  ──────►  VIN  ┐
                        │ PPK2 measures the current passing through
  DUT VDD ◄──────  VOUT ┘
  DUT GND ───────  GND
  • --vdd sets nothing in this mode, but the calibration uses it. Give the voltage the DUT really runs at. The default is 3.3. See the Principle page for how much a wrong value costs.
  • Nothing else may feed the DUT. Current that reaches it by a second path does not pass through the PPK2 and is not measured.
  • Nordic's dev kits have a current-measurement header for this: remove the jumper and put the PPK2 across it, VIN on the supply side.

Source meter mode

The PPK2 supplies the DUT. Add --source, and --vdd becomes the supply voltage, from 0.8 to 5.0 V.

  DUT VDD ◄──────  VOUT    PPK2 supplies and measures
  DUT GND ───────  GND

The PPK2 can supply up to 1 A. Above 400 mA the user guide recommends a second USB supply, on the USB POWER ONLY socket.

A DUT powered this way is off until a command switches it on, and off again when the command ends: the PPK2 cuts power when its serial port closes.

Digital inputs (optional)

The logic port has eight digital inputs, D0 to D7, sampled together with the current. They are optional. To use them, connect:

  • the signals you want to see to D0 to D7;
  • the logic port's GND to the DUT's ground;
  • the logic port's VCC to the DUT's VDD. The PPK2 uses it as the reference to tell high from low.

Step 3: connection check

Only one program can hold a PPK2, so quit the app first.

$ ppk2 list
PPK2  serial=A1B2C3D4E5F6
  /dev/cu.usbmodemA1B2C3D4E5F62   [data port]
  /dev/cu.usbmodemA1B2C3D4E5F64   [idle]

A PPK2 has two serial ports and only one carries data. ppk2 list shows which, and marks a port busy when another program holds it. With several PPK2s attached, add --serial A1B2C3D4E5F6 to any command that opens one.

$ ppk2 metadata
Calibrated: false
HW:         46575
IA:         60
VDD:        3300 mV
mode:       2 (Source meter)
R : [    1.002119e+03,     1.014783e+02,     1.033613e+01,     9.682840e-01,     5.643343e-02]
...

This is the calibration the PPK2 reports, plus the voltage and mode it was left in. Nordic's documentation gives the LED as breathing blue in Ampere meter mode and breathing red in Source meter mode.

Calibrated: false is normal

It does not mean the readings are wrong. See the Calibrated flag.

Step 4: first capture

In Ampere meter mode, the default:

ppk2 capture --out idle.csv --seconds 30

In Source meter mode, with the PPK2 powering the DUT at 3.3 V:

$ ppk2 capture --out first.csv --seconds 5 --source --vdd 3.3
opening session (Source meter mode, vdd=3300 mV)
capturing 5.00 s -> first.csv (Ctrl-C to stop early)
  [  1.0s]      100249 samples  mean  945.69 µA
  [  2.0s]      199681 samples  mean  826.16 µA
  [  3.0s]      300033 samples  mean  783.65 µA
  [  4.0s]      400385 samples  mean  761.46 µA
captured 500000 samples over 5.00 s (99936 Hz)

Progress goes to the terminal and the samples go to the file. Ctrl-C stops early and keeps what was recorded.

A capture switches the DUT on as it starts and off as it ends, so the boot is in the file. The current rises about 10 ms into it.

Step 5: reading the file

The CSV uses the 11 columns of the app's export, one row every 0.01 ms:

Timestamp(ms),Current(uA),D0-D7,D0,D1,D2,D3,D4,D5,D6,D7
0,0.000,00000000,0,0,0,0,0,0,0,0
0.01,0.000,00000000,0,0,0,0,0,0,0,0
0.02,0.000,00000000,0,0,0,0,0,0,0,0

A quick look with numpy:

import numpy as np

t_ms, ua = np.loadtxt("first.csv", delimiter=",", skiprows=1, usecols=(0, 1), unpack=True)
print(f"{len(ua)} samples over {t_ms[-1] / 1000:.2f} s")
print(f"mean {ua.mean():.2f} µA, max {ua.max():.0f} µA")
500000 samples over 5.00 s
mean 749.47 µA, max 164014 µA

See File formats for the columns in detail.

Step 6: opening the capture in the app (optional)

A name ending in .ppk2 gives a session file in the format the app saves and loads, and ppk2 convert makes one from a CSV:

$ ppk2 convert first.csv first.ppk2
wrote first.ppk2: 500000 samples at 100000 S/s (5.00 s)

Here the CSV is 20.1 MB and the session file 0.7 MB. See File formats for how far this format has been checked.

Recap

You have:

  • installed the ppk2 command and the Python package;
  • wired the PPK2 in Ampere meter mode or in Source meter mode;
  • checked the connection with ppk2 list and ppk2 metadata;
  • recorded a capture to a CSV file;
  • read the file with numpy, and converted it for the app.

Platform notes

macOS

The two ports are /dev/cu.usbmodem*.

Linux

The ports are /dev/ttyACM*. Your user must be allowed to open them, which usually means joining the dialout group:

sudo usermod -a -G dialout $USER    # then log out and back in

Some distributions use uucp instead. ls -l /dev/ttyACM0 shows the group.

Windows

The PPK2 shows up as two COM ports. Two things are not supported on Windows yet, because they use POSIX calls:

  • ppk2 power on --hold;
  • Ctrl-C during ppk2 run.

Nordic development kits

  • nRF52840 DK: set switch SW6 to "nRF only" to measure. Otherwise the interface chip stays on the measured supply, and its current hides that of the nRF52840.
  • nRF54L15 DK and nRF54LM20 DK: put the PPK2 across the current-measurement header. With everything else left connected, the nRF54LM20 DK idles at 1.4 µA with the bench firmware of this repository, as the validation shows.
  • After flashing, an nRF chip stays in debug mode and draws more until it is power-cycled. On the nRF54LM20 DK the same firmware idled at 330 µA after a flash and a reset. A capture power-cycles the DUT.

Next steps

  • Command reference: every command and option.
  • Recipes: flashing, the current of a marked region, long captures, comparing two builds.
  • Principle: what the numbers are.